?

단축키

Prev이전 문서

Next다음 문서

크게 작게 위로 아래로 댓글로 가기 인쇄 첨부
?

단축키

Prev이전 문서

Next다음 문서

크게 작게 위로 아래로 댓글로 가기 인쇄 첨부

 

Donghoon Han, Yang-Rae Kim, Chung Mu Kang, Taek Dong Chung*


Analytical Chemistry 2014, 86(12), 5991−5998
 

Publication online: May 20, 2014
Publication date: June 17, 2014
DOI: 10.1021/ac501120y
ISSN: 0003-2700
Journal country: United States
Publisher: AMER CHEMICAL SOC
URL: http://pubs.acs.org/doi/abs/10.1021/ac501120y
 

Abstract: We devised an electrochemical redox cycling based on three-dimensional interdigitated array (3D IDA) electrodes for signal amplification to enhance the sensitivity of chip-based immunosensors. The 3D IDA consists of two closely spaced parallel indium tin oxide (ITO) electrodes that are positioned not only on the bottom but also the ceiling, facing each other along a microfluidic channel. We investigated the signal intensities from various geometric configurations: Open-2D IDA, Closed-2D IDA, and 3D IDA through electrochemical experiments and finite-element simulations. The 3D IDA among the four different systems exhibited the greatest signal amplification resulting from efficient redox cycling of electroactive species confined in the microchannel so that the faradaic current was augmented by a factor of ∼100. We exploited the enhanced sensitivity of the 3D IDA to build up a chronocoulometric immunosensing platform based on the sandwich enzyme-linked immunosorbent assay (ELISA) protocol. The mouse IgGs on the 3D IDA showed much lower detection limits than on the Closed-2D IDA. The detection limit for mouse IgG measured using the 3D IDA was ∼10 fg/mL, while it was ∼100 fg/mL for the Closed-2D IDA. Moreover, the proposed immunosensor system with the 3D IDA successfully worked for clinical analysis as shown by the sensitive detection of cardiac troponin I in human serum down to 100 fg/mL.

 

Download: 22_Analytical Chemistry.pdf


  1. 30. Nanoscale electrocatalysis of hydrazine electro-oxidation at blistered graphite electrodes, ACS Appl. Mater. Interfaces 2016, 8(44), 30458–30466

    Date2018.02.22 By김양래 Views1818
    Read More
  2. 29. Electrochemical impedance spectroscopy at well controlled dc bias for nanoporous platinum microelectrode in embryo brain, ChemElectroChem 2016, 3(12), 2189−2195

    Date2018.02.02 Category2016 By김양래 Views838
    Read More
  3. 28. Light-guided electrodeposition of non-noble catalyst patterns for photoelectrochemical hydrogen evolution, Energy and Environmental Science 2015, 8(12), 3654−3662

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views1594
    Read More
  4. 27. Impact of surface chemistry on nanoparticle-electrode interactions in the electrochemical detection of nanoparticle collisions, Langmuir 2015, 31(43), 11932−11942

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views31189
    Read More
  5. 26. Time-resolved detection and analysis of single nanoparticle electrocatalytic impacts, Journal of the American Chemical Society 2015, 137(34), 10902−10905

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views70721
    Read More
  6. 25. Nucleation and aggregative growth of palladium nanoparticles on carbon electrodes: experiment and kinetic model, Journal of Physical Chemistry C 2015, 119(30), 17389−17397

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views293426
    Read More
  7. 24. Redox-dependent spatially resolved electrochemistry at graphene and graphite step edges, ACS Nano 2015, 9(4), 3558−3571

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views16865
    Read More
  8. 23. Surface coverage and size effects on electrochemical oxidation of uniform gold nanoparticles, Electrochemistry Communications 2015, 53(1), 11−14

    Date2016.02.02 CategoryPost-doc (2011~2015) By김양래 Views27814
    Read More
  9. 22. Electrochemical signal amplification for immunosensor based on 3D interdigitated array electrodes, Analytical Chemistry 2014, 86(12), 5991−5998

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views835
    Read More
  10. 21. Tunable decoration of reduced graphene oxide with Au nanoparticles for the oxygen reduction reaction, Advanced Functional Materials 2014, 24(19), 2764−2771

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views4632
    Read More
  11. 20. Modulation of quinone PCET reaction by Ca2+ ion captured by calix[4]quinone in water, Journal of the American Chemical Society 2013, 135(50), 18957−18967

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views1544
    Read More
  12. 19. Electrokinetic concentration on a microfluidic chip using polyelectrolytic gel plugs for small molecule immunoassay, Electrochimica Acta 2013, 110(1), 164−171

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views1387
    Read More
  13. 18. Enhanced electrochemical reactions of 1,4-benzoquinone at nanoporous electrodes, Physical Chemistry Chemical Physics 2013, 15(26), 10645−10653

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views1142
    Read More
  14. 17. Immunosensor based on electrogenerated chemiluminescence using Ru(bpy)32+-doped silica nanoparticles and calix[4]crown-5 self-assembled monolayers, Electroanalysis 2013, 25(4), 1056−1063

    Date2016.02.01 CategoryPost-doc (2011~2015) By김양래 Views642
    Read More
  15. 16. Graphene-incorporated chitosan substrata for adhesion and differentiation of human mesenchymal stem cells, Journal of Materials Chemistry B 2013, 1(7), 933−938

    Date2016.01.30 CategoryPost-doc (2011~2015) By김양래 Views857491
    Read More
  16. 15. Charged nanomatrices as efficient platforms for modulating cell adhesion and shape, Tissue Engineering, Part C: Methods 2012, 18(12), 913−923

    Date2016.01.29 CategoryPost-doc (2011~2015) By김양래 Views298274
    Read More
  17. 14. A BODIPY-functionalized bimetallic probe for sensitive and selective color-fluorometric chemosensing of Hg2+, Analyst 2012, 137(17), 3914−3916

    Date2016.01.29 CategoryPost-doc (2011~2015) By김양래 Views653
    Read More
  18. 13. In-channel electrochemical detection in the middle of microchannel under high electric field, Analytical Chemistry 2012, 84(2), 901−907

    Date2016.01.29 CategoryPost-doc (2011~2015) By김양래 Views938
    Read More
  19. 12. Gold microshell tip for in situ electrochemical raman spectroscopy, Advanced Materials 2012, 24(3), 421−424

    Date2016.01.29 CategoryPost-doc (2011~2015) By김양래 Views3108
    Read More
  20. 11. Synthesis of a graphene–carbon nanotube composite and its electrochemical sensing of hydrogen peroxide, Electrochimica Acta 2012, 59(1), 509−514

    Date2016.01.29 CategoryPost-doc (2011~2015) By김양래 Views1320
    Read More
Board Pagination Prev 1 2 Next
/ 2

로그인

로그인폼

로그인 유지